DEV-04 · Software development

Meter data validation tool

Catch recurring meter data problems before they undermine reports.

What to share
Sample readings and any rules you already use for timing, units and unusual values.
How we help
Build a checker that flags missing, repeated or implausible readings.
What you receive
A configurable checker, an exceptions file and a test dataset.

When this service helps

An energy report can look complete even if a source file contains missing readings, repeated records or a change in units. Analysts may only spot the problem when an unusual trend reaches management. A validation tool checks each file against agreed rules and gives people a way to distinguish a real outlier from a mistake. A clear record of the changes can also make recurring problems easier to raise with the team that supplies the data.

How we help

We agree which rules can be checked automatically and which cases require judgement. The tool keeps the original value alongside each flag so reviewers can see what happened and trace it to the source.

What you receive

The team can run checks consistently and identify which problems need attention before a report is published. The test results also help managers decide how many additional flags their staff can review to catch another kind of error.

An example for your business case

In an illustrative 1,000-record file with 20 known errors, a rule catches 18 and flags seven valid readings. A stricter check might catch one more error but add five false flags. Compare the impact of the extra error with the staff time involved before adopting the rule.

Start the discussion

Tell us which problems you see repeatedly and when they usually come to light. Mention who decides whether a flagged reading is valid. We can discuss starting with one file type and the few rules that make the greatest difference to your reporting.

Email [email protected] to start the discussion. Include DEV-04 if you have the reference, and let us know when you need to make the decision. We can agree how to share any sensitive material after the first conversation.

How it works

  1. Read the file
  2. Apply the checks
  3. Flag possible errors
  4. Review the results
Illustrative business case

How the checker performs on known errors

errors in the test file
20
errors found
18
valid rows flagged
7

Illustrative business case · DEV-04

Which meter checks are worth automating?

See how the example was calculated, which assumptions change the result and what to check with your own figures.

PDF · 2 pages · 92 KB

Read the full business case

DEV-04 · Meter data validation tool · OXETC business-case whitepaper · Version 2.0, November 2026

The management decision

Decide which errors would change a business decision and what it costs to investigate each flag. Use a file with known answers to test the balance between missed errors and unnecessary checks.

An energy report can look complete even if a source file contains missing readings, repeated records or a change in units. Analysts may only spot the problem when an unusual trend reaches management. A validation tool checks each file against agreed rules and gives people a way to distinguish a real outlier from a mistake. A clear record of the changes can also make recurring problems easier to raise with the team that supplies the data.

Worked example

A test file contains 1,000 records with 20 known errors. A rule catches 18 errors and flags seven valid records. Reviewers must handle the extra flags, and two known errors remain undetected.

Example figureWhat it represents
20Errors in the test file
18Errors found
7Valid rows flagged

What changes the answer

A stricter rule catches one more error and flags five more valid entries. Compare the consequence of the extra error caught with the additional review work before adopting it.

What to commission

Build a checker for one meter file format and agreed rules for gaps, repeated rows, units and unusual values.

We agree which rules can be checked automatically and which cases require judgement. The tool keeps the original value alongside each flag so reviewers can see what happened and trace it to the source.

How to judge the result

A reviewer can distinguish detected errors, missed errors and valid records flagged in the agreed test dataset.

Compare reviewer time with the consequences of missed errors. Recheck the agreed sample whenever rules change so any gain or loss is visible.

Decision worksheet

Project detailStarting point for your team
Decision ownerMeter data or reporting operations lead. Name the person who will approve the next step.
Records to gatherSample readings and any rules you already use for timing, units and unusual values.
Agreed outputA configurable checker, an exceptions file and a test dataset.
Decision dateRecord the deadline, any unresolved assumption and who will confirm it.

Discuss this case

Tell us which problems you see repeatedly and when they usually come to light. Mention who decides whether a flagged reading is valid. We can discuss starting with one file type and the few rules that make the greatest difference to your reporting.

Email [email protected] and mention DEV-04. All figures in the worked example are illustrative.